Mining Incidents

Tiny Creek No 2 MineCoal

Coal River Mining LLC · Underground
Sumerco, Lincoln County, WV · Abandoned
MSHA Mine ID: 4608835
Fatalities
1
Total incidents
88
Years on record
2001–2008
Latest incident
May 2008

Fatalities at this mine

1 recorded
Struck by falling object

Unintentional roof fall occured in the H6 entry causing fatal injuries.

Reportable incidents

87 on file (excluding fatalities above)

2008 · 5 incidents

Accident type, without injuries

Weathered stack shale, mixed into stack sand stone., seperated in L line of x cuts, allowing roof to fall. Fall was found on a weeklt exam.

Accident type, without injuries

Unintentional roof fall occurred on 1-a northwest mains, #4 entry, spad #3332, 920' outby 005 mmu, 30' long x 19' wide x 8' high. Bolted with 6' torque tension and 8' point anchor bolts, fall was breakered off.

Accident type, without injuries

2nd Northwest Mains, #4 entry between spad #341-345, 9000' outby section, unintentional roof fall occurred. 30' long x 18' to 19' wide x 6' high, wet weathered soap stone, bolted with 6' resin bolts fully grouted.

Struck by flying object

EE had just helped block up scoop to cross track. When his weight was put on blocking it flew out striking him in face. Was crossing track to set tail piece for section pulling back to new set up to start pillaring.

Accident type, without injuries

An unintentional roof fall occurred. 30' long x 20' wide x 9' to 10' high. Was bolted with 6' tension & 8' point anchor bolts at spad #3838, #6 entry 005 mmu, 1-A northwest mains, 2200' outby section. Primary escapeway was blocked, production was stopped. Everyone was brought outby till escapeway was rerouted.

2007 · 16 incidents

Accident type, without injuries

Unintentional roof fall occurred in intersection of #3 entry at spad #3831 1700' outby 005 MMU 3rd SW Mains. Fall was 18' wide x 18' long x 8' high, bolted with 6' tension rebar & 8' point anchor bolts; area is cribbed off.

Accident type, without injuries

Unintentional roof fall occurred 10000' outby working section 40' long x 18' wide x 6' high. Between #1 & #2 entry at spad #480 2nd Northwest Mains. Fell on top of service bolter; cribbed off, will not be recovered at this time. Found during weekly exam.

Accident type, without injuries

Unintentional roof fall occurred in #2 entry, spad #3791, 1st left 1-A NW mains 005 section. 45' long x 19' wide x 8' to 9' high.

Over-exertion in lifting objects

EE was hanging miner cable so he could clean #5 entry, when he felt pain in his lower back.

Accident type, without injuries

Unintentional roof fall occurred at spad #2568, #7 entry, 2nd north west mains 5800' out-by section. 30' long X 19' wide X 6' to 7' thick. Area was cribbed off and escapeway was rerouted.

Struck by falling object

The victim had just walked over to the power center and was talking to co-worker when a piece of rock 13 x 30"" x 9"" fell striking the victim in the head and shoulders.

Accident type, without injuries

Unintentional roof fall occurred. 10' high x 19' wide x 80' long, wet weathered slip (domed out with 2"" rider) in #3 entry 30 ' inby spad #3538, 900' outby face on 003 section.

Over-exertion in wielding or throwing objects

Employee was helping change bull gear on 4A belt head; while swinging sledge hammer he felt pain in elbow and shoulder. He worked light duty until 1-4-08 while taking physical therapy. 1-4-08 had lazor surgery to repair torn rotator cuff.

Caught in, under or between a moving and a stationary object

Employee was helping raise belt line with scoop when he got his hand between scoop bucket and rail of belt structure causing broken finger.

Over-exertion in pulling or pushing objects

EE was helping roll draw rock off the top of miner, when he felt pain in his chest.

Accident type, without injuries

Unintentional roof fall occurred, 25' in length, 12'-15' in width, 4' thick, in belt entry 3400' outby working section. Was bolted with 4' bolts. Cleaned area up & rebolted with 6' point anchor bolts.

Over-exertion in lifting objects

Employee was lifting a bucket of plaster over his head onto an overcast when he felt pain in his lower stomach.

Over-exertion (Not Elsewhere Classified)

Employee was climbing on top of belt line to take deludge down during recovery process when he felt pain in lower stomach. He worked light duty till doctor's test determined he needed surgery on 3-5-07.

Over-exertion (Not Elsewhere Classified)

Inj EE was helping another EE raise rub rail up to pin in, when he felt pain in groin area. EE went to dr 1/18/07 and returned to work, started having problems & dr performed surgery 5/2/07.

Accident type, without injuries

Unintentional roof fall occurrd 40 ' inby Spad # 2803, # 5 Entry, 1st Right, 2nd North East Mains 003 Section, 600' out by 4-B Tail. Bolted with 6' torque tension bolts, 20' Wide X 20' Long X 6' High. Slicky sided big slip.

Accident type, without injuries

Unintentional roof fall occurred 20'x20'x8' high, wet laminated slicky sided. Formation in intersection, bolted with 6' torque tension and 8' point anchor, found on preshift at spad #2800 #4 entry 1st right 2nd north east mains.

2006 · 22 incidents

Accident type, without injuries

Unintentional roof fall occurred on 2nd northeast mains, #1 entry, 100' outby spad #2567. 30' long x 20' wide x 10' high. 2000' outby 003 section. Bolted with 6' torque tension bolts & 8' point anchore bolts in return air course. Found making weekly exam.

Struck against stationary object

Employee was tightening bolts on a hyd. pump on a feeder when socket & ratchet slipped off the bolt head causing him to strike his hand on a shield & cutting his hand.

Struck by falling object

He was installing a bolt, the bolt head broke off and the plate and pan struck him on his left forearm and cut a 3"" cut.

Accident type, without injuries

Unintentional roof fall occurred in neutral airway 20 x 20 x 8' high was found during pre shift of track 3rd Northwest Mains #5 entry spad #1108. Roof support was 6' torque tension & 8' cable bolts. Wet weather fault.

Accident type, without injuries

Unintentional roof fall occurred in intake airway, not affecting escapeway 20' long x 19' wide x 8' high in intersection, was found while traveling weekly in 2nd Northwest Mains #8 entry spad #351. Roof support was 6' resin. Wet weather slip.

Fall to the walkway or working surface

Employee was walking in #4 Entry approx. 50' inby the feeder and slipped on loose, slick rocks. He fell and twisted his right ankle.

Caught in, under or between a moving and a stationary object

EE was attempting to roll rock out of track when it rolled back the wrong way pinning his leg betwene motor and rock, He started having trouble with his knee and went to dr and dr profomed microsopic surgery on his knee 4/9/07 causing him to be off work accident occured 100' outby spad #572 2nd northwest mains.

Accident type, without injuries

Unintentional roof fall occured 80' inby spad #286. 30' in lenght, 18' wide, 6' thick, wet, weathered mixed roof (Big Slip). Cribbed off and cleared escapeway.

Accident type, without injuries

Miner was backing out of lift when shuttle car went down behind miner, allowing rock to fall on miner and causing miner to get stuck at 4:30pm. Before we could get s/car running and miner moved 7' of rock fell on the miner, causing us to use retriever on 003 section.

Accident type, without injuries

An unintentional roof fall occurred in xcut between #4 & #5, entry 4300' outby face on 3rd northwest mains. 30"" in length, 19'wide & 5'thick at spad #1087 & 1086 in neutral air course.

Accident type, without injuries

An unintentional roof fall occurred in #1 entry 4400' outby face on 3rd northwest mains, 50"" in length, 19"" wide & 6'thick. 200' inby spad # 983 in return air course.

Accident type, without injuries

UNINTENTIONAL ROOF FALL OCCURRED IN RETURN AIR COURSE, 3RD NORTHWEST MAINS, #1 ENTRY, SPAD #1203. WET, WEATHERED ROOF.

Accident type, without injuries

UNINTENTIONAL ROOF FALL OCCURRED IN #3 ENTRY, SPAD #1150, 3RD NORTHWEST MAINS IN A NEUTRAL ENTRY. WET, WEATHERED ROOF.

Fall from ladders

EE was building an intake stopping on 005 section. He was standing on ladder finishing wedging the stopping when a piece of draw rock fell and hit on his head and down his back causing him to fall off ladder to the ground. He was about three steps on ladder when he fell landing on his back.

Fall onto or against objects

EE fell behind tool sled, loading material on sled, stumbled on rock, fell on piece of metal and cut right thigh.

Accident type, without injuries

Unintentional roof fall occurred in #3 entry at spad #1183. 20' x 20' x 6' height. Type of bolt used 6' torque tension and 8' point anchor.

Accident type, without injuries

UNINTENTIONAL ROOF FALL OCCURRED IN #8 ENTRY SPAD #562 2ND NORTH WEST MAINS. 50'L X 20'W X 6' TO 8'H, APPEARED TO BE SHALIE WEATHERED ROOF. OCCURRED IN INTAKE AIR COURSE. NOT AFFECTING ESCAPEWAY. TYPE OF ROOF BOLT USED 6' RESIN.

Accident type, without injuries

An unintentional roof fall occurred on 2nd Northwest Mains, #4 entry spad #573 20' x 20' x 6' to 8' high. Appeared to be shalie weather roof in intake aircourse. Not affecting escapeway. Type of roof bolt used was 6' resin.

Accident type, without injuries

Wet shale seperated with a rider seam unintentional roof fall occured in intake aircourse 20'x20'x6' thick appeared to be weathered and shalie roof.

Struck by... (Not Elsewhere Classified)

He was working on #2 belt head drive chains. He was separating the straps on the chain by driving a chisel between the link & strap. He was going to move the chisel to the other side & hit it sideways & chisel flew up & hit him in the lip.

Caught in, under or between a moving and a stationary object

EE was standing behind bolter dropping trailing cable when bolter backed up to miss s/car cable, while doing so smashed EE foot between bumper and floor.

Caught in, under or between a moving and a stationary object

Employee was using a slate bar, assisting miner oper. in removing rock off of miner, when slate bar rolled smashing hand between slate bar & miner.

2005 · 11 incidents

Accident type, without injuries

Unintentional roof fall ocurred in Return Air Course. 7000' outby 005 on 2nd Northwest mains in #2 entry, spad #476. 30' x 19' & approx. 6'thick. Appeared to be weathered & shale roof. Fall will be cleaned up & bolted back with extra support added.

Accident type, without injuries

UNINTENTIONAL ROOF FALL OCCURRED AT THIS TIME BLOCKING 2 MRS UNITS. 20' X 20' APPROXIMENTLY 6' THICK. IN INTERSECTION AND APPEARED TO BE A SLIP ON THE 003 SECTION 5TH LEFT 3 WEST MAINS #2 ENTRY SPAD 1476. DEVELOPED RECOVERY PLAN, SECURED AREA, RECOVERED MRS UNITS AND TIMBERED AREA OFF.

Struck by... (Not Elsewhere Classified)

Setting spad in #1 entry, fell off ladder. Sliced finger on Roof Bolt that employee was holding.

Caught in, under or between a moving and a stationary object

SHUTTLE CAR LOST POWER WHILE ON FEEDER AT SECTION DUMPING POINT WHILE OPERATOR WAS USING MANUAL PUMP OFF BRAKE AND SCOOP WAS PULLING ON CAR. HE WALKED ALONG SIDE OF CAR AND WAS CAUGHT BETWEEN RIB AND SHUTTLE CAR

Over-exertion in lifting objects

Employee was cleaning on walkway side of his belt. While lifting on a piece of draw rock, he felt something pull in his rt. upper arm.

Accident type, without injuries

Wet shale separated pull loose.

Accident type, without injuries

Stack Shale Roof weathered separated allowing intersection to fall, no plans to rehab, area has been cribbed off.

Struck by... (Not Elsewhere Classified)

EE was operating roof bolter, while pushing roof bolt up with drill pot roof bolt bent and roof bolt plate struck ee in rt. forearm just below the elbow causing laceration.

Accident type, without injuries

Roof in this area is a shale sandstone mix with streaks of coal, and some formations shale sand mix separated at app 5 to 6 ft allowing intersection to fall. Area had been bolted with 4 ft long bolts, fall has been cribbed off; roof control plan has been changed since this was developed.

Accident type, without injuries

Stack shale area with thin coal streaks present; weathered shale separated allowed to fall loose from main roof.

Accident type, without injuries

THIS IS A STACK SHALE AREA WITH THIN STREAKS OF COAL AND WEATHERING CONDITIONS, WHICH ALLOW THE THIN LAYERS TO SEPARATE & PULL AWAY FROM THE MAIN ROOF.

2004 · 7 incidents

Struck by falling object

While installing roof a piece of thin shale rock fell out and struck him on left side of face.

Accident type, without injuries

STACK SHALE ROOF WEATHERED & DETERIORATED ALLOWING SHALE TO SEPARATE & SLIP AWAY FROM MAIN ROOF. FALL DID NOT AFFECT VENTILATION OR TRAVELWAY. FALL CRIBBED OFF ON ALL SIDES, NO PLAN TO REHABILITATE THIS AREA.

Accident type, without injuries

The lowest point in a swag area with wet shale roof with slick backs. Shale weathered and alloyed shale to pull loose from main roof.

Accident type, without injuries

WET SHALE AREA WITH SLICK BACKS. SLIP AREA PULLED LOOSE ALLOWING ABOUT 20-50' X 19'W X 6-7'THICK. THIS AREA HAS BEEN CRIBBED OFF NO AIRWAYS OR TRAVEL WAS AFFECTED.

Accident type, without injuries

Wet area with slikk backs and formations in roof with rider sham, allowed roof to separated above roof bolt machine and fell, fall has been cribbed off and travel way remarked, no plans to rehab this area.

Struck by falling object

EE WAS INSTALLING 8-FT-LONG CABLE BOLTS IN #8 ENTRY INTERSECTION. WHILE PUSHING THE ROOF BOLT UP, IT GOT STUCK. EE TRIED TO PULL THE BOLT BACK OUT OF THE HOLE. THE BOLT CAME OUT OF THE DRILL POT ON THE ROOF BOLTER, AND THE ROOF BOLT PLATE STRUCK THE EE ON THE NOSE AND IN THE FACE.

Accident type, without injuries

Fall was found during a weekly exam of area. Area was developed 3-19-01 and is approx 6000' from face. Fall is 6' high by 40-45' long by 19' wide between #8 and #9 entry. Roof control plan was being followed and 6' glue bolts used.

2003 · 12 incidents

No Value Found

WHILE WALKING TO BACK OF ROOF BOLTER TO GET SUPPLIES, EMPLOYEE WAS STRUCK ON THE HEAD BY A ROCK APPROXIMATELY 4' SQUARE. IT SLID DOWN HIS BODY, STOVING HIS NECK, SHOULDER AND BACK.

Struck by falling object

EE WAS BOLTING THE ROOF WHEN A PIECE OF ROCK FELL STRIKING HIM ON HIS LEFT ARM AND CUTTING IT IN 2 PLACES.

Accident type, without injuries

AN AREA OF ROOF 35'LONG - 8'HIGH FELL OUTBY SPAD 563 IN #5 ENTRY, NEUTRAL. THE ROOF IS SLATE, ROOF IS DRY, A RIDER COAL SEAM 8""THICK IS 8'ABOVE COAL SEAM. AREA WAS BOLTED WITH 4,6 & SOME 8' FULLY GROUTED BOLTS & SOME CRIBS. AREA WAS DEVELOPED 9/2001 & IS 1200'FROM SECTION. AREA HAS BEEN BREAKERED OFF. FALL WILL NOT BE MOVED.

Accident type, without injuries

A SECTION OF ROOF FELL IN THE #6 ENTRY NEUTRAL AT SPAD #710. FALL IS 30'LONG, 18'WIDE & 3-5'THICK. AREA DEVELOPED 12-01, BOLTED WITH 4'& 6'FULLY GROUTED RESIN. AREA IS 1500'FROM ACTIVE WORKIN GS. AREA IS SLICK SIDED SLATE. AREA WILL NOT BE REHABILITATED.

Accident type, without injuries

AN AREA OF ROOF FALL FELL IN THE #8 ENTRY INTAKE AT SPAD #803 (OUTBY) AREA WAS DEVELOPED IN 3-5-02. AREA WAS BOLTED WITH 4' X 6' FULLY GROUTED BOLTS. ROOF WAS WET LAMINATED SLATE. FALL IS 50' LONG, 18' WIDE, 3 TO 5 FT THICK. FALL WILL NOT BE MOVED. STOPPING LINE WILL BE MOVED OVER ESTABLISHING ESCAPEWAY.

Accident type, without injuries

AN AREA OF ROOF FALL ON #3 BELT AT BX#16. AREA BOLTED WITH 4&5 RESIN BOLTS. AREA IS SLICK-SIDEDSLATE. NO COAL RIDER SEAM PRESENT AREA IS DRY. DEVELOPED 5-25-01. AREA IS 6500FT FROM ACTIVE SECTION. FALL WILL BE MOVED, AREA HAS BEEN BRAKERED OFF FALL DID NOT EFFECT MOVEMENT OF MEN OR ESCAPEWAYS. (FALL IS 30' X 4' X 18')

Accident type, without injuries

AN INTERSECTION ON THE TRACK #5 ENTRY NEUTRAL AT #22 BREAK ON #4 BLET FELL. AREA WAS DEVELOPED ON 11-01 & WAS BOLTED WITH 4"" & 6' FULLY GROUTED RESIN. FALL IS 20'X20'X 5' THICK. ROOF IS SLATE WITH A RIDER COAL SEAM AT 3'; ROOF IS DRY. FALL AREA WILL BE MOVED & REBOLTED. RIDER COAL SEAM IS 8"" - 12"" THICK.

Accident type, without injuries

AN INTERSECTION AT SPAD 836 #8 ENTRY INTAKE FELL. AREA WAS BELTED WITH 4'X 6'FULLY GROUTED BOLTS, AREA HAD MIXED ROOF, WATER IS PRESENT A 3""RIDER SEAM IS PRESENT AT 4'. FALL AREA SOFTENED UP & FELL OUT AROUND 6'BOLTS, PULLING THE 4'BOLTS OUT. AREA LATER FELL OUTBY FOR APPROX. 1 BK TO SPAD 826. FALL WILL NOT BE MOVED.

No Value Found

EMPLOYEE WAS GOING TO RAISE THE BATTERY LID ON A LOCOMOTIVE. THE LID WAS STUCK & WOULDN'T RAISE. HE STRAINED HIS LOWER BACK.

Accident type, without injuries

AN INTERSECTION AT THE NORTH OF #3 LEFT MAINS IN #7 ENTRY INTAKE FELL. AREA IS 20' X 20' X5' THICK. AREA DEVELOPED 2/02. SHALE ROOF, NO WATER, NO RIDER SEAM. BOLTED WITH 4' & 6' FULLY GROUTED BOLTS. AREA WAS BREAKERED OFF. AREA WILL BE REHABILITATED. MEN WERE MOVED OUTBY FALL AREA & WORK ON FALL HAS BEGUN. FALL AREA IS 1000' FROM SECTION FACE.

Accident type, without injuries

AREA FELL BETWEEN #2 & #3 ENTRIES RETURN, 3,000' FROM ACTIVE SECTION. AREA DEVELOPED 5-10-01. ROOF IS SLATE BOLTED WITH 4'& 6' RESIN. FELL RIB TO RIB, 3-4' THICK. THERE IS A 1 INCH RIDER ABOUT 2'-3' UP. FALL IS DIRECTLY ACROSS FROM SPAD 299. FALL WILL NOT BE MOVED.

Accident type, without injuries

AN INTERSECTION ON #3 BELT AT #40 BK FELL, SOMETIME OVER THE WEEKEND. FALL IS 1 BK INBY SPAD 468. AREA FELL RIB TO RIB, 4-5' THICK, AREA WAS BOLTED WITH 6' BOLTS. AREA WAS DEVELOPED 6-01. AREA IS BREAKERED & DANGERED OFF. ROOF IS SLATE, A RIDER SEAM IS PRESENT ON LEFT SIDE ONLY AT 4'. FALL WILL BE MOVED.

2002 · 2 incidents

Accident type, without injuries

A SECTION OF ROOF 30' LONG X 6-8' THICK, RIB TO RIB, FELL, 2 BRKS OUTBY SPAD #787 IN #4 ENTRY MEUTRAL ABOUT 600' FROM SECTION. AREA WAS SUPPORTED WITH 6' FULLY GROUTED BOLTS. AREA WAS DEVELOPE D 2-8-02. ROOF WAS LAMINATED SHALE & SANDSTONE, NO WATER OR RIDER SEAM PRESENT.

Struck by falling object

EE WAS STANDING AT FRONT WHEEL OPERATORS SIDE WATCHING OTHER INSTALL LAST BOLT IN ROW. WHEN A SLAB WATCHING OTHER INSTALL LAST BOLT IN ROW. WHEN A SLAB OR LOOSE PIECE OF SLATE ROCK DISLODGED S TRIKING HE IN THE HEAD AND SHOULDER PIECE OF ROCK FELL FROM BETWEEN BOLTS.

2001 · 12 incidents

Accident type, without injuries

A (SLIP) OR (HORSES BACK) FELL, 1 BREAK INBY SPAD 460. FALL WAS IN THE CROSSCUT THAT SPAD 469 WAS IN. FALL WAS APPROX 4'THICK, COVERING AN AREA 20' BY 20' OR INTERSECTION AREA.

Accident type, without injuries

ROOF FALL BREAK 41, 1 BREAK IN BY SPAD 296. FALL IS 20 FT BY 20 FT BY 4 FT THICK. AREA BOLTED WITH 4' BOLTS (RESIN FULL GROUT) AREA DEVELOPED 5-1-01 4,000 FT OUT BY FACE AREA. BREAKERED OFF FALL. FALL WAS FOUND 11-9-01 ON WEEKLY EXAMINATION.

Struck by falling object

EE WAS MOVING THE MINER, NOTICEING A PIECE OF LOOSE SLATE, EE STOPPED THE MINER, TOOK A SLATE BAR AND PULLED THE LOOSE SLATE, WHEN A PIECE OF THE SLATE STRUCK EE ON THE FOOT.

Caught in, under or between (Not Elsewhere Classified)

EMPLOYEE WAS SHOVELING BELT LINE AND AT AROUND #3 BELTHEAD WHILE SHOVELING EMPLOYEE'S HAND GOT CAUGHT IN BOTTOM ROLLER, BREAKING HIS HAND.

Struck by... (Not Elsewhere Classified)

PUTTING UP A BOLT WITH 1/2 HEADER & BOLT STARTED TO BEND. VICTIM TRIED TO SPIN BOLT & 1/2 HEADER CAME AROUND AND STRUCK HIS RT WRIST.

Struck by falling object

EE HAD HIS HAND RESTING ON THE SIDE OF BOLTING MACHINE WHEN A PIECE OF SLATE FELL & HIT HIS HAND.

Struck by falling object

EE WAS BOLTING TOP AND A SMALL PIECE OF ROCK FELL AND HIT HIM ON SHOULDER. THE ROCK 2"" THICK X 8"" SQUARE. FELL FROM ABOUT 8' HIGH.

Struck by... (Not Elsewhere Classified)

EMPLOYEE WAS REMOVING A WIRE ROPE FROM A SHUTTLE CAR WHEN IT CAME LOOSE AND SPRANG BACK AND STRUCK HIS LEFT INDEX FINGER CUTTING IT.

Accident type, without injuries

WHILE MAKING HIS WEEKLY EXAM, THE FOREMAN & MSHA INSPECTOR FOUND A FALL IN THE 37 ENTRY RETURN ARI COURSE OFF OF 001 SECTION. THE FALL WAS APPROX 20' LONG X 20' WIDE X 5' THICK. AREA DEVEL9OPE D IN 1ST WEEK OF MAY 2001. BOLTED WITH 48"" RESINBOLTS. ROOF SLIP, WET WITH COAL STREAK AT 5'.

Accident type, without injuries

A ROOF FALL WAS DISCOVERED BY THE FOREMEN AT APPROX. 12:30 P.M. ON 6-29-01 IN THE #8 ENTRY, A NETURAL AIRWAY. THE FALL WAS 1 BK OUTBY SPAD 323 IN THE INTERSECTION. IT WAS APPROX 30 FT LONG X 1 8 FT WIDE X 4 1/2 FT THICK. WET LAMINATED SHALE ROOF. NO EE OR EQUIPMENT WERE INVOLVED.

Accident type, without injuries

WHILE MAKING THE REQUIRED WEEKLY EXAM, THE FIRBOSS DISCOVERED A ROOF FALL IN THE RETURN AIR COURES, #1 ENTRY, 1 BK OUTBY SPAD #313. THE FALL WAS BETWEEN THE BLOCK IN THE ENTRY TO WAS APPROX. 3 0 FT LONG X 17 FT WIDE X 4 1/2FT THICK NO EQUIPMENT WERE INVOLVED.

Over-exertion in lifting objects

EE SAID HE WAS THROWING MINE SLACK OUT OF ROADWAY & FELT PAIN IN HIS RIGHT SHOULDER. RESON FOR LATER REPORT: EE DID NOT INFORM MGMT. HE WAS OFF OVER AN INJURY UNTIL 7-13-01. 1ST L9OST WORK DAY 7-9-01.