UNINTENTIONAL ROOF FALL. FALL MEASURED 20' LONG X 18' WIDE X 40' HIGH. AREA MINED 2/22/06. NO INJURIES OR PROPERTY DAMAGE. ROOF PREVIOUSLY SUPPORTED WITH 6' TORQUE TENSION AND 6' DOUBLE LOCK BOLTS. ONLY ENTRANCE WAS DANGERED OFF AND BROW SUPPORTED WITH 3 CRIBS. FALL MOST LIKELY WILL NOT BE SUPPORTED OR CLEANED.
Stony River MineCoal
Wolf Run Mining Company · Underground
Controlled by Core Natural Resources Inc
Mt Storm, Grant County, WV · Abandoned and Sealed
MSHA Mine ID: 4608631
- Fatalities
- 0
- Total incidents
- 5
- Years on record
- 2001–2006
- Latest incident
- Feb 2006
No fatalities recorded at this mine.
Reportable incidents
5 on file2006 · 1 incident
Accident type, without injuries
2005 · 2 incidents
Struck by falling object
Employee was in a seated position operating a radio remote controlled continuous miner when a small piece of rock fell from the roof & rib and struck him on the back of his shoulder.
Struck by falling object
Employee was roof bolting #5 Entry. He was on the ""off side"" of the roof bolter in a squat position with the left knee on the mine floor and the right leg posed in a 90"" position. While beginning to drill the first hole a piece of rock being drilled fell from the roof, broke against the canopy, and struck the right knee.
2001 · 2 incidents
Struck by... (Not Elsewhere Classified)
INJURED WAS STRAIGHTENING A BENT ROOF BOLT WHEN THE ROOF BOLT SPUN AROUND STRIKING HIM ON LEFT WRIST CAUSING A FRACTURE.
Accident type, without injuries
ROOF FALL FROM LAST OPEN XCUT BETWEEN #5 & #6 TO LAST XCUT BETWEEN #8 TO #9 FALL 240' LONG, 8' HIGH.